Hercules-Elephant
STANDARD EQUIPPED PRE FABRICATED MODULES
FOR LOADGING AND THECNOLOGIC INTEGRATED SYSTEMS
Mod.: HERCULES – ELEPHANT
![]() |
![]() |
![]() |
Type of product:
SELF bearing prefabricated BUILDING with characteristics of transport equals to standard containers in order to grant the structural integrity to dynamic solicitations due to handling.
Outer covering TOTALLY metal TYPE, INTERGRATED with load bearing STRUCTURE.
APPLICATION FIELD Type of use
HousING AND ACCOMODATION MODULES, integrated technological SYSTEM in climate conditions with high thermal ranger, industrial and corrosive environmental. ON-SHORE AND OFF-SHORE installations and in marine environment.
TECHNICAL CHARACTERISTICS
This description has the scope to define the particular technical REQUIREMENTS for DESIGN AND CONSTRUCTION OF containerized monolithic structures, pre-assembled in workshop, realised in 4 standard types in order to be used in the most different logistic services, usefull for a simple and fast start up in operative function with following requisites:
- High resistance to climate and heaviest atmospherically conditions, that allow the installations both in marine environments with corrosive conditions and also of very high humidity both in deserted environment and in zones with industrial atmospheres.
- Easily transportable via land (road or rail road) or via sea, USING OF THE SAME FACILITIES OF STANDARD CONTAINERS FOR LIFTING, HANDLING and fixing on all means of transport.
- Possibility to join the single MODULES with a simple bolting, in order to obtain full pavilions on one or more levels.
- Insulation of the lateral walls, of the roof and the floor with material and thickness that satisfy the specific needs compared to environmental conditions here under reported.
- STRUCTURE TOTALLY METALLIC TYPE, welded and sized in order to satisfy the conditions of loading and consequent solicitations.
- Outer coverings of the walls, ceiling and floor realized with safe materials of the best quality and in harmony with the international standards about FIRE PROTECTION AND REACTION.
SIZE CHARACTERISTICS
External dimension
There are expected 4 standard types of outer sizes:
- Type HERCULES W (length x width x high) mm: 12.190 [40’]x2.990 [10’] x2.896 [9’5”]
- Type HERCULES N mm 12.190 [40’]x2.438 [8’]x2.896 [9’5”]
- Type ELEPHANT W mm 6.055 [20’]x2. 990 [10’]x2.896 [9’5”]
- Type ELEPHANT N mm 6.055 [20’]x2. 438 [8’]x2.896 [9’5”]
Internal dimension
Here under there are reported internal dimension based on the 4 types; about the inner high there are reported 2 values , the solution with standard floor [S] and the option of the raised floating floor [F] (see figure in the next page)
- Type HERCULES W (length x width x high S/F) mm: 11.970x2.770x2.585 / 2.310
- Type HERCULES N mm 11.970x2.218x2.585 / 2.310
- Type ELEPHANT W mm 5.835x2.770x2.585 / 2.310
- Type ELEPHANT S mm 5.835x2.218x2.585 / 2.310
![]() |
Internal partition walls